Item Infomation


Title: 
Assessment of the effectiveness of secondary anti-damp insulation in heritage buildings made of historic brick: the current state of knowledge, research gaps and perspectives
Authors: 
Szemiot, Natalia
Hoła, Anna
Sadowski, Łukasz
Issue Date: 
2023
Publisher: 
Springer
Abstract: 
Destruction caused by excessive moisture is a common problem in heritage buildings made of brick. Historic buildings usually have walls that of different constructions, i.e. walls with all joints filled, walls without filled vertical joints, and walls with a layered arrangement. Excessive moisture causes brick cavities, reduces the load-bearing capacity of walls, is unsightly, and can lead to the destruction of walls or the failure of a building. Secondary anti-damp insulation is used to protect the brick walls of historic buildings. However, there has not been enough research to confirm the effectiveness of secondary anti-damp insulation. This type of insulation is performed with the use of the injection method, with various factors (such as soils, the type of injection material, etc.) that affect the effectiveness of the insulation being taken into account. There is also insufficient research on how injection material penetrates brick.
Description: 
CC-BY
URI: 
https://link.springer.com/article/10.1186/s40494-023-01043-x