Thông tin tài liệu
| Nhan đề : |
| Intercomparison of equipment measuring radon activity concentration in the air—an example from a hydrotechnical structure in Dobromierz (SW Poland) |
| Tác giả : |
| Lidia, Fijałkowska-Lichwa Tadeusz A., Przylibski Maciej, Norenberg |
| Năm xuất bản : |
| 2023 |
| Nhà xuất bản : |
| Springer |
| Tóm tắt : |
| The semi-conductor SRDN-3a probe, an AlphaE detector with a silicon diode in a diffusion chamber, an AlphaGUARD monitor with an ionization chamber and CR-39 track detectors had been tested simultaneously in long-term measurements conducted in the technical corridor of Dobromierz dam. The passive detectors were exposed twice: for 56 days, and 117 days, others in parallel, with a 1-h data recording interval. The data distribution was tested with the Shapiro–Wilk test and outliers in the critical region were identified using Shewhart control charts. The correctness was evaluated by a z-score test recommended by the IAEA. The characteristics of outliers for each detectors are determined by the location of the critical region (a two-sided region and a positive skew). |
| Mô tả: |
| CC BY |
| URI: |
| https://link.springer.com/article/10.1007/s10967-023-08882-9 https://dlib.phenikaa-uni.edu.vn/handle/PNK/8219 |
| Bộ sưu tập |
| OER - Khoa học Tự nhiên |
XEM MÔ TẢ
125
XEM TOÀN VĂN
64